pf = power failure, at this point I attempted to enter test mode and can not get in (Air Dry / Start Cancel buttons for three seconds). I have 115v going to the board with the door closed and I have continuity over both halves of the door switch. With the door open continuity stops as does the voltage at the switch. After the door is open the display goes blank and touch controls don't respond until the breaker is turned off then back on.
The odd thing is I have around 40volts going to all but 4 of the lines to plug P5, the user interface. Not sure what the voltage readings are supposed to be but if it runs on 115v then why not use 115v, or is its a dc connection then 12v right?
I'm suspecting the board but I prefer to measure twice and hammer once.
Thanks in advance,
John C
The odd thing is I have around 40volts going to all but 4 of the lines to plug P5, the user interface. Not sure what the voltage readings are supposed to be but if it runs on 115v then why not use 115v, or is its a dc connection then 12v right?
I'm suspecting the board but I prefer to measure twice and hammer once.
Thanks in advance,
John C