Need a lil help. Element burnt "open" twisted back into peace and cleaned lint from blower. Verified clear vent and good flow out of house. Assumed lint and teenager overloaded. Four days later open element again. Twisted back again rechecked all. Temp in drum and shut it down when I saw 178 and climbing.
Checked thermistor and it's reading 12 k at 62 deg. From what I can find that's about right "10 k @ 77"
If this it true do I Ned to change one of the boards or both and how can I test out the boards
Thanks in advance